内容标题38

  • <tr id='PdQJm9'><strong id='PdQJm9'></strong><small id='PdQJm9'></small><button id='PdQJm9'></button><li id='PdQJm9'><noscript id='PdQJm9'><big id='PdQJm9'></big><dt id='PdQJm9'></dt></noscript></li></tr><ol id='PdQJm9'><option id='PdQJm9'><table id='PdQJm9'><blockquote id='PdQJm9'><tbody id='PdQJm9'></tbody></blockquote></table></option></ol><u id='PdQJm9'></u><kbd id='PdQJm9'><kbd id='PdQJm9'></kbd></kbd>

    <code id='PdQJm9'><strong id='PdQJm9'></strong></code>

    <fieldset id='PdQJm9'></fieldset>
          <span id='PdQJm9'></span>

              <ins id='PdQJm9'></ins>
              <acronym id='PdQJm9'><em id='PdQJm9'></em><td id='PdQJm9'><div id='PdQJm9'></div></td></acronym><address id='PdQJm9'><big id='PdQJm9'><big id='PdQJm9'></big><legend id='PdQJm9'></legend></big></address>

              <i id='PdQJm9'><div id='PdQJm9'><ins id='PdQJm9'></ins></div></i>
              <i id='PdQJm9'></i>
            1. <dl id='PdQJm9'></dl>
              1. <blockquote id='PdQJm9'><q id='PdQJm9'><noscript id='PdQJm9'></noscript><dt id='PdQJm9'></dt></q></blockquote><noframes id='PdQJm9'><i id='PdQJm9'></i>
                400-021-9919
                品名:   地下工程用空调除湿机
                型号:   
                品牌:   众有品牌除湿机系列
                说明:   除湿机组系统的运作由除湿机的内循环(制冷剂循⌒环系统)、除湿机的◥外循环(空气循环系统)组成;
                除湿机的内循环:通过压缩机的运行→排气口排出高温高压的气体→进入冷凝器冷却→变成低温高压气体→通过毛细管截流→变→成低温低压的液体→通过蒸发器蒸发吸热▃→回到压缩机变成低温低压的气体,如此循环往复。
                除湿机的外循环:在正常开机的情况下→通过风机☉的运行→潮湿的空■气从进风口吸入→经过蒸发々器→蒸发器将空气中的水份吸附在铝片上→变成干燥的空气(→经过◥冷凝器散热)→从出风口吹出。
                 地下工程用空调除湿机
                 

                地下工程用除湿空调机是我公司集四十余年空调除湿设备的专业设计和制造经验,通过大量的数据采集和分析,针对地下工程或类似地下工程使用环境,系列化开发了这一新型除湿空调设备,适用于国防工∏程、人防工程、地铁车站、航天基地、地下商场、地下娱乐中心等既有一般空调又有除湿要求的场所。

                本系列产品运用了全新的设计理念,针对地下工程的热湿负荷特征度身定制, 并采用了大量新◆材料、新技术和新工艺,机组同时具有中央空调机和除湿机两种功能,真正实现一机多用,各项性能◢指标优越,堪称新时代的节能环保先锋。

                工作原理:

                除湿机组系统的运作由除湿机的内循环(制冷剂循环系统)、除湿机的外循环(空气循环系统)组成;

                除湿机的内循环:通过压缩机的运行排气口排出高温高压的气体进入冷凝器冷却变成低温高压气体通过毛细管截流变成低温低压的液体通过蒸发器蒸发吸热回到压缩机变成低温低压的气体,如此循环往复。

                除湿机的外循环:在正常开机的情况下通过风机的运▆行潮湿的空气从↑进风口吸入经过蒸发器蒸发器将空气中的水份吸附在铝片上变成干燥的空气(经过冷凝器散热)从出风口吹出。

                机组特点:

                1. 功能多样,一机多用:
                机组具有良好的工程适应性,可以㊣实现空调、除湿和除湿调温三种工况运行模式。机组在空调模式为全负荷运行,可以有效地消除内余热,大道降低空气温度的目的,适合于工程热符合大的时期;机组在除湿模式为部分负荷运行,主要用Ψ于除湿№,使用于工程余热较小、余湿较大的时期,可以在设备能调的配合下,实现低风量运行,确保工︼程内相对湿度满足要求,特别适用于地下工程的平时维护管理运行;机组在除湿〖调温模式为全负荷运行,适用于地下工程的平时维护管理运行;机组在除湿调温模式为全负荷运行,适用于平战结合工程在过渡季节和小余热、大余温工况的运行,可以有效地消除室内余∩温。

                2. 节能运行--热回收:
                利用冷凝热作为空调』机的二次加热源,降低了机组的运行成本,节约了运行能耗,全面提高机组的节能指标。

                3. 结构型式"个性化"
                地下工程用除湿空调机采用模块化设计理念和组合式结构,由混风过滤段、冷却再热段、送风段和主机段组合而成。自由拼装,连接简单,拆卸方便。

                4. 能量调节:
                机组通过使用高性能的螺杆压缩机或涡旋压缩机,分级调节实现多种工况运行模式,同时采用变速风机与压缩机的能调相结合。

                5. 直接蒸发,高效制冷:
                机组为自带冷源(直接蒸发式)多功能组合式除湿空调设备,集制→冷系统、通风系统和控制系统于一体,与用冷冻水作为二次冷媒的机组相比,简单、高效,效率提高10%以上;蒸发器配列设计,充分利用蒸发器面积,在50%负荷时,蒸发器效率提高30%以上,制冷效〇率高。机组安装方便,现场只需接▲线、接管即可运行。

                6. 压缩机及冷配:
                压缩机和主要制冷配件均采用国际著名的产品,通过制冷系统科学▂合理的优化设计,机组噪音低、运行可靠、能效比高。

                7. 换热器:
                水侧换热器为壳管式换热器,采用高效换热管;空气侧换热器为铜管套铝翅片式换热器,采用美国OAK换热器生产线制造。换热器结构紧凑、压力好、换热效率」高。

                8. 环保工质,"绿色"概念:
                机组采用满足淘汰CFC工质国家方案要求的R22制冷剂,有利地地球环境。公司亦可按用户要求订制R407CR134aHFC工质的除湿机。

                9. 外壳:
                机组ξ 采用国内外流行的高强度铝型材框架;拆弯件采用日本AMADA数控设备加工,具有优良的外观质量。机组采用拼装式结构,整体结构紧凑,美观大方,及富现代气息。

                10. 全自动控◆制:
                机组全面应用现代控制技术,优化控制模型,采用先进的PLC作为控制系统,自带控制柜,确保控↓制精度,且实现机电一体化。机组配有友好简单的全中文人机界面,标准配置为文本显示器,亦可按用户∮要求采用触摸屏。

                11. 可选择的网络功能:
                机组可通过调制√解调器或以太网模块实现设备与远程计算机连接,利用INTERNET进行数据交换,对机组进行远程监控和故障分析,帮您快速准确地预测及排除故障,还可通过PROFIBUS总线实现局▃域网络机组的群控功能。

                12. 多重保护:
                机组设有过载、短路、缺相、过热、高低压等保¤护,以及风机、水泵、防火阀连锁保护。

                13. 功能段介绍:
                混风过滤段:使新风和回风进行混合,并∞对混合空气进行过滤处理,主要包括新风法兰、回风法兰和初效过滤器。
                冷却再热段:对空气进行相应的热湿处理,主要包括蒸发器和风冷冷凝器。
                送风段:将处理后的空气输送到目的地,主要包括变速风机和减震装置,出风方式为上出风。
                主机段:对制冷工质进行压缩冷凝处理,主要由压缩机和水冷∏冷凝器等制冷元器件和电器控制系统组成(对型机还包括风机)。
                其它:本公司还可以根据用户实际需求增设中效过滤段、中间段等辅助功能段,以满足不同场合的空气处理要◎求

                说明:
                  进风方式规定如下:面对↘控制器,回风口在左侧的为左进风,回风口在右侧的为右进风;
                  本系列机组的冷却水进出口与控制器呈异侧分布,即控制器在〗正面,冷却水进出口在背面。

                型号示例: CK12-DX 表示名义风量为12000m3/h,回风方式为端部回风的南方型地下工程用除湿空调机,面对机组控制器,回风口在右侧。

                南方型-基本型性能参数◣表:

                型 号

                CK9-DX

                CK12-DX

                CK15-DX

                CK20-DX

                CK25-DX

                CK30-DX

                CK35-DX

                CK40-DX

                CK45-DX

                制冷量

                KW

                62

                72

                95

                120

                148

                175

                210

                242

                276

                除湿量

                Kg/h

                32

                40

                50

                75

                90

                100

                120

                135

                150

                机外余压

                Pa

                500

                500

                650

                650

                700

                700

                700

                700

                600

                机组功率

                KW

                18.5

                22.5

                30.6

                41

                55.6

                63

                74

                80

                99

                南方型-I型性能参数表:

                型 号

                CK9-DX-I

                CK12-DX-I

                CK15-DX-I

                CK20-DX-I

                CK25-DX-I

                制冷量

                KW

                62

                72

                95

                120

                148

                除湿量

                Kg/h

                32

                40

                50

                75

                90

                机外余压

                Pa

                500

                600

                650

                650

                700

                机组功率

                KW

                19.4

                26

                30.6

                41

                55.6

                北方型-基本型和S型性能参数表:

                型 号

                CK9-BDX

                CK12-BDX

                CK15-BDX

                CK20-BDX

                CK25-BDX

                CK30-BDX

                CK35-BDX

                CK40-BDX

                CK45-BDX

                制冷量

                KW

                62

                72

                95

                120

                148

                175

                210

                242

                276

                加热量

                KW

                24

                27

                36

                45

                48

                60

                72

                90

                99

                除湿量

                Kg/h

                32

                40

                50

                75

                90

                100

                120

                135

                150

                加湿量

                Kg/h

                4

                8

                10

                12

                15

                36

                44

                48

                56

                机外余压

                Pa

                450

                450

                550

                550

                550

                600

                600

                6000

                500

                机组功率

                KW

                30.5

                37.6

                55.4

                73.5

                83.5

                102.3

                114.3

                144.2

                165.2

                机组名义工况:

                蒸发器侧

                冷凝器侧

                备注

                水冷式

                风冷式

                干球温度

                相对湿度%

                进水温度

                出水温度

                干球温度

                湿球温度

                 

                27

                60

                30

                35

                35

                --

                --

                 